ORDER HERE - Quick-dissolving, biodegradable thermogel PLGA-g-PEG polymers

Vivos Inc.
(OTCQB: RDGL)

Vivos Inc. (OTCQB: RDGL)Vivos Inc. (OTCQB: RDGL)Vivos Inc. (OTCQB: RDGL)
Home
PLGA-g-PEG Polymers
RadioGel®
IsoPet®
PRnT™
Press Releases
IDE Submission
Subscribe
The History of Vivos Inc.
The Peltier Chiller
Quarterly Reports
SEC Filings
Research Papers
Meet The Team
FAQ's
Contact Us

Vivos Inc.
(OTCQB: RDGL)

Vivos Inc. (OTCQB: RDGL)Vivos Inc. (OTCQB: RDGL)Vivos Inc. (OTCQB: RDGL)
Home
PLGA-g-PEG Polymers
RadioGel®
IsoPet®
PRnT™
Press Releases
IDE Submission
Subscribe
The History of Vivos Inc.
The Peltier Chiller
Quarterly Reports
SEC Filings
Research Papers
Meet The Team
FAQ's
Contact Us
More
  • Home
  • PLGA-g-PEG Polymers
  • RadioGel®
  • IsoPet®
  • PRnT™
  • Press Releases
  • IDE Submission
  • Subscribe
  • The History of Vivos Inc.
  • The Peltier Chiller
  • Quarterly Reports
  • SEC Filings
  • Research Papers
  • Meet The Team
  • FAQ's
  • Contact Us

  • Home
  • PLGA-g-PEG Polymers
  • RadioGel®
  • IsoPet®
  • PRnT™
  • Press Releases
  • IDE Submission
  • Subscribe
  • The History of Vivos Inc.
  • The Peltier Chiller
  • Quarterly Reports
  • SEC Filings
  • Research Papers
  • Meet The Team
  • FAQ's
  • Contact Us

PLGA-g-PEG polymers from VIVOS

Deliver your active pharmaceutical with quick-dissolving, biodegradable thermogel consisting of poly(lactide-co-glycolide)-graft-poly(ethylene glycol). Initially developed at Pacific Northwest Laboratories and further refined by a collaboration between Vivos Inc. and Akina Inc. The graft PLGA-g-PEG dissolves in cold water within 2-5 hours rather than 1-2 days as is typical for PLGA-PEG-PLGA triblocks enabling ease of drug delivery development.


Model Usage Example: BSA-FITC

A hydrogel solution (30%) was created by dissolving VP002 into PBS. And into this solution an equivalent of 1 mg/ml BSA-FITC was added to the vial. 1mL of the solution from the vial was pipetted into three different Float-a-lyzer G2 dialysis cartridges (300kDa MWCO), for a load quantity of 1mg BSA-FITC per cartridge. The cartridges were incubated in 40 ml of phosphate buffered saline with 0.05% Tween 20 (PBST) with orbital agitation at 100 RPM at 37°C. At each time point the outer layer was removed and refreshed with new PBST and tested for BSA-FTIC content by UV-Vis absorbance at 496 nm compared to a calibration curve. Test done in triplicate, chart below shows average ± standard deviation.

Ordering information

  • Price does not include shipping/handling and applicable sales tax
  • This product is for research use only and it is not intended for use in humans or for in vitro diagnostic use.

Order Polymers

Polymer Name & Comments

Poly(lactide-co-glycolide-co-graft-poly(ethylene glycol))
VP001 - PLGA-g-PEG65:35 LA:GA, Mn 1500 - 3500, molar PEG content: 40 - 60%No. VP001 Certificate of AnalysisVP002 - PLGA-g-PEG75:25 LA:GA, Mn 1500 - 3500, molar PEG content: 40 - 60%No. VP002 Certificate of AnalysisResearch using PolySciTech product: VP002VP003 - PLGA-g-PEG85:15 LA:GA, Mn 1500 - 3500, molar PEG content: 40 - 60%No. VP003 Certificate of Analysis

Vivos Inc.

Vivos Inc. & Akina Inc.

Vivos Inc. has the goal of developing new products and therapies to improve patient care. Since then, we have grown into a leading biotech company with a global presence and a reputation for innovation and excellence. Together with PolySciTech - A Division of Akina, Inc. are excited to offer 3 PLGA-g-PEG polymers to research centers worldwide.